Example of Type III Fractured Abutment Screw Recovery with only Hand Instruments – 0036
This implant case showcases an example of a Type III Fractured Abutment Screw Recovery with only Hand Instruments.
This implant case showcases an example of a Type III Fractured Abutment Screw Recovery with only Hand Instruments.
This case study illustrates Another Example Of An Initial IMR Attempt Without Microscope Guidance Or Precision Tooling.
This case illustrates how wrong restorative components led to two abutment screw failures in two years leading to an abutment screw rescue.
The patient presented on referral for identification of the implant in the #8 site and recovery of a fractured abutment and retained abutment screw which had lost its drive geometry.
The patient presented on referral for retrieval of a fractured zirconia abutment from a Straumann 4.1 BL implant in the #6 site.