An Iatrogenic Mechanical Failure When A Conical Abutment Was Used On A TSV Implant – 0031
This case illustrates an example of an Iatrogenic mechanical failure when a conical abutment was used on a TSV implant.
This case illustrates an example of an Iatrogenic mechanical failure when a conical abutment was used on a TSV implant.
This case illustrates how wrong restorative components led to two abutment screw failures in two years leading to an abutment screw rescue.
The patient presented for retrieval of a fractured healing abutment screw from a Straumann 4.1 RC BL implant in the #13 site
Latrogenic Inclusion of Impression Material Resulting in an Early Abutment Screw Fracture. The patient presented for retrieval of a fractured abutment screw from a Straumann 4.8 BL implant in the #19 site.
The patient presented on referral for retrieval of a fractured abutment and abutment screw from a BlueSkyBio MaxNP implant 4.3 in the #30 site.
The patient presented for recovery of an abutment and abutment screw from a Straumann 4.8 BL RC implant in the #30 site.
The patient presented on referral form Dr. S. for retrieval of a fractured abutment screw from a Noble Active 3.5 implant in the #29 site.
The patient presented on referral from his general dentist with a fractured Ankylos abutment in the #2 site.
The patient presented on referral for retrieval of a fractured zirconia abutment from a Straumann 4.1 BL implant in the #6 site.
The case involves a failed abutment screw in a Nobel trilobe 4.3 implant in the #3 site.